1) Normal inlet temperature Air-cooling Refrigerated Air Dryer
Capacity (m3/min): 0.7, 1.2, 2.4, 3.8, 6.5, 8.5, 10, 13.8, 17, 23, 27, 33, 45, 55, 60
2) Normal inlet temperature Air-cooling Refrigerated Air Dryer
Capacity (m3/min): 0.7, 1.2, 2.4, 3.8, 6.5, 8.5, 10.7, 13.5, 17, 23, 27, 33, 45, 55, 60
Working condition and Technical data
Inlet temperature Normal inlet
Temperature45 centidegree
High inlet
Temperature80 centidegree
Cooling method Air-cooling
Ambient temperature 38 centidegree
Design dew point 1.7 centidegree
Refrigerant R-22
Inlet pressure 0.2-1.0MPa
Pressure drop 0.02MPa
2. Purge Desiccant Air Dryer
Capacity(m3/min): 1.2, 2.4, 3.8, 6.5, 8.5, 11, 13.5, 17, 22, 27, 32, 42, 55, 65, 85, 110, 160, 210
Working condition and Technical data
Inlet temperature 0-45 centidegree
Inlet oil content 0.01ppm
Working pressure 0.6-1.0Mpa
Dew point -20 centidegree- -70 centidegree
Purge air 12%
Desiccant activated alumina & molecular sieve
Purge mode heatless purge
Working method continuing alternative working between two towers
Working periods T=10-20min.
Control mode micron computer auto controlling
Installation mode indoor, non-basement
Working elements
Heatless Purge Desiccant Compressed Air Dryer using micro holes in the desiccant itself, adsorbing the moisture in the air because of capillary, desorbing it by pressure drop and adsorbing extra-heat. Currently, the equipment is making up of two towers, controlled by the Program Controller, the two towers working alternately, one is for adsorbing, the other is for desorbing, in this way continually circulating the work.